- Infrared thermography
- Thermal anomalies may indicate moisture-related patterns; temperature alone does not prove a leak.
- Moisture meters & mapping
- Non-invasive and pin-type measurements, comparative readings and documented moisture distribution.
- Controlled rain / pressure testing
- Water application and selected pressure methods to assess suspected façade or glazing entry points.
- Electronic roof membrane testing
- Specialized methods for compatible membrane systems, arranged through qualified providers where needed.
- Inspection cameras & borescopes
- Visual review of accessible cavities and hard-to-reach areas.
- CCTV drainage inspection
- Pipe condition and obstruction assessment through qualified operators.
- Concrete imaging
- GPR and ultrasonic methods may reveal reinforcement and selected internal features; they do not directly locate every leak.
Concrete scanning and thermal imaging provide supporting information; they do not by themselves establish all leak sources or structural safety. Regulated engineering or architectural opinions are prepared by appropriately qualified professionals.